Magnetic Flux Leakage
This equipment uses Magnetic Flux Leakage as a detection tool. The powerful magnetic
bridge introduces a magnetic flux into the material to be inspected. The strength of the
magnetic bridge allows for near saturation of the inspected material. Any localized reduction in
the thickness of the inspected material will result in a flux leakage at the surface. A series of
sensors are placed between the poles of the magnetic bridge to detect these leakage fields.
The strength of the leakage field is a function of volume loss and is not a reliable indication of
remaining wall thickness. Although the amplitude of the signal generated by the sensors gives
some relative severity information, it is not recommended that amplitude alone be used for
accept/reject criteria purposes. Flux leakage should only be used as a detection tool.
Quantitative information can only be obtained using ultrasonic assessment of the areas
identified by the magnetic flux leakage scanner.